European Laboratory Tests
Laboratory Tests And Conclusions
"The Hydrosmart Water Conditioner unit, reduced lime-scale deposits on the test vessel by 84% over a 60-day period under laboratory conditions."
The following are extracts from Independent European Laboratory Reports where tests were carried out on the Hydrosmart water conditioning units to European (EU) standards.
Hydrosmart has no connection with this laboratory or its associated companies.
Unit installed on water supply for 7 day water hardness test. Before installation hardness of water 7.25° dH. Thirty minutes after installation reading was 5.75° dH. Other results as follows:
Conclusions:
Test 2: Turbidity
Test 1: Hardness test
(°dH = Degree German Hardness 1°dH = 1.25 English Hardness (°Clark). 1°dH =10mg CaCo3 = 1.25° Clark.
dH
20/8
5.2521/8
5.2522/8
5.2523/8
5.2524/8
4.7525/8
4.5026/8
4.5027/8
4.2528/8
4.25
The hardness of water was reduced from 7.25° dH to 4.25° dH over a test period. The Hydrosmart unit reduced water hardness by 41% under test conditions.
Shows the amount of calcium (and /or magnesium) salts affected by the unit and "neutralised' i.e made incapable of forming scale.
Two month laboratory trial installed to laboratory water supply
Before Test/
5days
10 days
15 days
30 days
2 mths
Ph
7.4
7.3
7.2
7.2
7.3
7.3
Calcium (ppm)
370
350
350
360
340
340
Turbidity
(ppm)
5
95
90
75
45
45
% of Calc
Susp.
0
96
92
90
90
90
Depth of
Scale mm
1.3
1.0
0.7
0.5
0.3
0.2

Conclusions
The boiling vessel used in the trial contained a hard deposit of some 1.3mm calcium salts, accrued over 5 years use of the laboratory water supply. The Hydrosmart unit reduced depth of lime scale from 1.3mm to 0.2mm over a 2 month period. The unit installed and used as per manufacturer's instructions performed well over the test period. It can be said to perform its main function of removing and preventing lime scale in a very effective way, particularly in light of the test conditions, which were very rigorous. Other effects of the treatment are as claimed, (i.e. enhanced effectiveness of soaps and detergents, eventual extension of the working life of heating elements etc.)
The Hydrosmart Water Conditioner unit, reduced lime-scale deposits on the test vessel by 84% over a 60-day period under laboratory conditions.
Note: Chemical testing for TDS levels (total dissolved solids) in the treated water, decreased rapidly within a few days. This is because testing chemicals need free electron bonds to react with, in order to get a reading. As these bonds are neutralised by the Hydrosmart resonance frequencies, an artificially low reading occurs. However, as no crystals are forming and existing scale is being removed, the readings accurately reflect the de-scaling and scale prevention abilities of the Hydrosmart System.